3-minute product tour Urgent incident email
Protection · Industrial systems

Assess industrial control systems
within operating constraints

We first confirm operating conditions and stop criteria, then assess assets, network segmentation, and remote access with reference to IEC 62443.
If critical information and communications infrastructure requires a statutory assessment, we’ll discuss the scope of the preliminary assessment during the consultation.

#OTSecurity#ICS#SmartFactory#SupplyChain

In operationWe sequence checks to keep production lines running. We prepare vulnerability analysis and assessments for critical information and communications infrastructure in line with the applicable designation requirements. Service standards

Service scope and process

Dedicated analysis nodes for each customer

Each customer’s analysis runs on dedicated nodes. Customers use separate compute resources and storage.

Every decision has a record of the supporting evidence

A single record identifies the engine behind the decision, the logs it relied on, and the action it recommended. You can submit that record as audit evidence.

Past decisions can be rerun

We record the model and policy versions used for each decision. If you question a decision from last month, you can rerun it on the same data and compare the results.

People make the final decision

AI classifies and summarizes alerts. Analysts approve response actions, including server isolation and account lockouts, before they run.

Safety rules for industrial control equipment

When equipment is running,
here’s how we run checks

Even a brief halt in factory operations can cause significant losses. OT validation therefore follows a different sequence and different stop criteria from IT validation. We use the operational guidance in NIST SP 800-82 and IEC 62443 as our baseline.

Step 1

We monitor passively

We use mirrored network traffic to identify assets and communication paths without sending packets to the equipment.

Step 2

We validate in a test environment first

We first validate each scenario on a testbed or spare equipment. If we need to check live equipment directly, we agree on the scope and stop criteria with the equipment owner.

Step 3

We run checks during maintenance

We perform essential checks on operational equipment during scheduled maintenance or planned downtime, with the equipment owner present.

Principles

We don’t send write commands

We keep write commands, including PLC configuration changes and stop or start commands, off production equipment. We stop the checks immediately if we detect network delays.

After the site survey, we document the stop criteria, participants, and protocols and equipment models in scope. Work begins once the plan is signed.

Service configuration

OT security services

OT security assessment and consulting

We identify factory OT assets such as PLCs, HMIs, and engineering PCs.
We assess network segmentation, remote access, patch management, account management, and backups against IEC 62443 and NIST SP 800-82 and provide an improvement plan.

Key capabilities

Asset inventory

We analyze traffic passively and build an asset inventory without interacting with the equipment.

Network architecture analysis

We assess the boundary between IT and OT networks and design the industrial DMZ (i-DMZ).

Regulatory readiness

We identify applicable regulatory requirements, including Korea's guidelines for protecting national core technologies.

Improvement roadmap

We plan improvements in phases around the equipment's scheduled maintenance windows.

Process

On-site investigation

Review equipment and network

  • Asset inventory

Assessment

Checks by zone using IEC 62443

  • Assessment findings

Design

Design improvements to the network

  • Network improvement design

Roadmap

Set the implementation order

  • Roadmap

OT anomaly detection and monitoring

We establish normal operating patterns for traffic using industrial protocols such as Modbus and OPC UA.
We alert you when an unauthorized device connects or an unusual control command appears.

Key capabilities

Industrial protocol analysis

We interpret protocol traffic down to individual commands.

Baseline normal operations

We establish a baseline for which devices normally exchange which commands.

No production impact

We analyze copies of traffic from a mirror port. The monitoring system sends no traffic to the equipment.

OT Incident Response

For urgent matters, start your email subject with “URGENT:”. We coordinate on-site support with the staff responsible for the equipment.

Process

Sensor installation

Connect the sensor to a mirror port

    Baseline learning

    Learn normal operating patterns

      Security monitoring

      Detect unusual network traffic

        Response

        On-site support during an incident

          Deployment inquiries

          Discuss your security needs

          Tell us about your operating environment and the security scope you need, and we’ll walk you through applicable configurations.

          Talk to Genox
          about scope and timing.

          Talk to us